Rev. 1.0 19 January 1998
P
o
w
e
r
F
a
u
l
t
P
e
r
s
i
s
t
e
n
t
S
w
i
t
c
h
H
e
a
t
e
r
M
a
g
n
e
t
P
o
w
e
r
S
u
p
p
l
y
7
L
o
c
a
l
E
s
c
9
8
7
L
o
c
a
l
E
s
c
9
8
4
R
e
m
o
t
e
6
5
1
3
2
0
E
n
t
e
r
+
/
-
.
F
u
n
c
t
i
o
n
M
e
n
u
N
e
x
t
M
e
n
u
N
o
r
m
a
l
D
i
s
p
l
a
y
C
u
r
s
o
r
D
a
t
a
E
n
t
r
y
F
u
n
c
t
io
n
s
M
o
d
e
O
u
t
p
u
t
I
n
h
i
b
i
t
O
F
F
O
N
Lake Shore Cryotronics, Inc. • 575 McCorkle Blvd. • Westerville, OH 43082-8888
PH: 614-891-2243 • FAX: 614-891-1392
Methods and apparatus disclosed and described herein have been developed solely on company funds of Lake Shore Cryotronics, Inc. No government or other contractual support or
relationship whatsoever has existed which in any way affects or mitigates proprietary rights of Lake Shore Cryotronics, Inc. in these developments. Methods and apparatus disclosed
herein may be subject to U.S. Patents existing or applied for. Lake Shore Cryotronics, Inc. reserves the right to add, improve, modify, or withdraw functions, design modifications, or
products at any time without notice. Lake Shore shall not be liable for errors contained herein or for incidental or consequential damages in connection with furnishing, performance, or
use of this material.
USER'S MANUAL
Model 647
Magnet Power Supply
Vue de la page 0
1 2 3 4 5 6 ... 71 72

Résumé du contenu

Page 1 - Magnet Power Supply

Rev. 1.0 19 January 1998 PowerFaultPersistentSwitch HeaterMagnet Power Supply7LocalEsc987LocalEsc984Remote651320Enter+/-.FunctionMenuNextMenuNorm

Page 2

Lake Shore Model 647 Magnet Power Supply User’s Manual Forward viiiSAFETY SUMMARY Observe the following general safety precautions during all phases

Page 3 - TABLE OF CONTENTS

Lake Shore Model 647 Magnet Power Supply User’s Manual Introduction 1-1CHAPTER 1 INTRODUCTION 1.0 GENERAL This chapter covers Features (Paragraph 1.

Page 4 - Chapter/Paragraph Title Page

Lake Shore Model 647 Magnet Power Supply User’s Manual Introduction 1-21.2 SPECIFICATIONS Below are performance specifications for current with a 1

Page 5 - Table of Contents

Lake Shore Model 647 Magnet Power Supply User’s Manual Introduction 1-3Agency Approvals: The Model 647 complies with the following requirements: UL 1

Page 6 - LIST OF TABLES

Lake Shore Model 647 Magnet Power Supply User’s Manual Introduction 1-41.3 OPERATING CHARACTERISTICS Many Model 647 MPS operating characteristics id

Page 7 - FOREWORD

Lake Shore Model 647 Magnet Power Supply User’s Manual Introduction 1-51.3.2 Low Noise, High Stability Current Regulated Output Model 647 MPS: Main

Page 8

Lake Shore Model 647 Magnet Power Supply User’s Manual Introduction 1-6 This Page Intentionally Left Blank

Page 9

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-1CHAPTER 2 INITIAL SETUP AND CONNECTIONS 2.1 INSPECTING AND UNPACK

Page 10 - Forward

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-22.4 CONNECTING THE MPS TO POWER Read and thoroughly understand se

Page 11 - INTRODUCTION

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-3Use this procedure to connect input power to the MPS: 1. Loosen th

Page 12

Lake Shore Model 647 Magnet Power Supply User’s Manual A MAGNET POWER SUPPLY CONFIGURATION Sales Order Number: _______________________________ MP

Page 13

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-42.5.2 Shielding, Grounding, and Noise For noise reduction, tightl

Page 14 - Four-Quadrant Power

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-52.5.6 MPS Analog Current And Voltage Monitoring Connections The MP

Page 15

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-62.5.8 Remote Sense Connections The factory configures the MPS to

Page 16 - Introduction

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-7Use the procedure below and see Figure 2-5 to connect multiple MPS

Page 17 - CHAPTER 2

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-88. Verify all connections as summarized in Table 2-5. 9. To add

Page 18 - MPS Line Voltage Limits

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-92.7 POST-INSTALLATION INSTRUCTIONS The MPS is electrically and mech

Page 19

Lake Shore Model 647 Magnet Power Supply User’s Manual Setup & Connections 2-10 This Page Intentionally Left Blank

Page 20

Lake Shore Model 647 Magnet Power Supply User’s Manual Operation 3-1CHAPTER 3 OPERATION 3.0 GENERAL This chapter covers seven areas: MPS Front Panel

Page 21

Lake Shore Model 647 Magnet Power Supply User’s Manual Operation 3-23.3 GENERAL DISPLAY DESCRIPTION In general, screen displays are split into two

Page 22 - MPS Rear View

Lake Shore Model 647 Magnet Power Supply User’s Manual Operation 3-33.5.2 Output Only Screen Press the OUTPUT ONLY Function key to fill the display

Page 23

Lake Shore Model 647 Magnet Power Supply User’s Manual Table of Contents iTABLE OF CONTENTS Chapter/Paragraph Title Page List of Illustrations...

Page 24 - 12345678

Lake Shore Model 647 Magnet Power Supply User’s Manual Operation 3-43.7 FUNCTION MENU 3 SCREEN Press Function Menu to display Function Menu 1. Pres

Page 25

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-1CHAPTER 4 REMOTE OPERATION 4.0. GENERAL Either of two computer interfaces

Page 26 - Setup & Connections

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-24.1.2 IEEE-488 Command Structure The Model 647 supports several command

Page 27 - OPERATION

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-3The Status Byte Register consists of a single data byte containing seven b

Page 28 - + 0.00 V

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-44.1.3.2 Standard Event Status and Standard Event Status Enable Registers

Page 29

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-54.1.4.2 Run The Example QuickBasic Program Use the following procedure to

Page 30 - 1.0 0 V

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-6Table 4-1 Sample BASIC IEEE-488 Interface Program ' IEEEEXAM.BAS

Page 31 - REMOTE OPERATION

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-7 National Instruments GPIB0 configuration GPIB-PC2/2A Ver 2.1 Primary G

Page 32

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-84.2. SERIAL I/O INTERFACE RS-232C is a standard of the Electronics Indus

Page 33

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-94.2.1 Serial Interface Hardware Configuration Below is a technical descri

Page 34 - Remote Operation

Lake Shore Model 647 Magnet Power Supply User’s Manual Table of Contents ii Chapter/Paragraph Title Page 3 OPERATION...

Page 35

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-10Table 4-3 Sample BASIC Serial Interface Program ' SEREXAM.BAS

Page 36

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-114.3 SUMMARY OF IEEE-488/SERIAL INTERFACE COMMANDS Below is an alphabetic

Page 37

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-124.3.1.1 Operational Commands Description Below is a list of MPS Operati

Page 38

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-13RI?: Remote Inhibit Status Query Input: RI? Returned: 0 if the remote in

Page 39

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-144.3.1.2 Interface Commands Description The MPS Interface Commands below

Page 40

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-154.3.1.3 Ramping Commands Description The following MPS Ramping Commands

Page 41

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-164.3.1.4 Current Zero Commands Description The following MPS commands co

Page 42

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-174.3.1.5 Current Step Limit Commands Description The following MPS comman

Page 43

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-184.3.1.6 Common Commands Description The MPS Common Commands below are i

Page 44 - Terminator Query

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-19 *IDN?: Identification Query Input: *IDN? Returned: Manufacturer, Model

Page 45 - Active Ramp Segment Query

Lake Shore Model 647 Magnet Power Supply User’s Manual Table of Contents iiiChapter/Paragraph Title Page 6 OPTIONS AND ACCESSORIES ...

Page 46 - Current Zero Status Query

Lake Shore Model 647 Magnet Power Supply User’s Manual Remote Operation 4-20 *SRE: Enables Status Reports In The Service Request Enable Register Inp

Page 47

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 5-1CHAPTER 5 ERROR MESSAGES AND TROUBLESHOOTING 5.0 GENERAL This ch

Page 48

Lake Shore Model 647 Magnet Power Supply User’s Manual Troubleshooting 5-2No delay is allowed (CAL AND ID switch 7 OFF, down) and multiple MPS opera

Page 49 - Instrument Reset Command

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 5-3Rail Fault Detected Excessive DC rail voltage (unable to return p

Page 50 - Wait-to-Continue Command

Lake Shore Model 647 Magnet Power Supply User’s Manual Troubleshooting 5-45.3 CALIBRATION NOTE: Calibration is only as accurate as the current monit

Page 51 - CHAPTER 5

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 5-520. Convert DVM voltage reading to current. A reading of +0.5123

Page 52

Lake Shore Model 647 Magnet Power Supply User’s Manual Troubleshooting 5-614. Set output current to +100 Amps. The DVM should read about +66 mV. Af

Page 53

Lake Shore Model 647 Magnet Power Supply User’s Manual 5-7 Troubleshooting 5.6 IEEE-488 INTERFACE CONNECTOR (When Model 6224 Option Is Present) Con

Page 54 - Troubleshooting

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 5-8 This Page Intentionally Left Blank

Page 55

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 6-1CHAPTER 6 OPTIONS AND ACCESSORIES 6.0 GENERAL This chapter cover

Page 56

Lake Shore Model 647 Magnet Power Supply User’s Manual Table of Contents iv LIST OF ILLUSTRATIONS Figure No. Title Page 1-1 Four-Quadrant Po

Page 57 - Figure 5-6 Model 2003 RJ-11

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 6-2in the mechanical orientation or in the direction of either the

Page 58 - Options & Accessories

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 6-36.2.4 Operation To access field monitoring, press Function Menu,

Page 59 - OPTIONS AND ACCESSORIES

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 6-4 BUNI? Magnetic Field Units Query Input: BUNI? Returned: Eith

Page 60 - Options & Accessories

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 6-56.4 ACCESSORIES Accessories are devices that perform a secondary

Page 61 - BFLD? Magnetic Field Query

Lake Shore Model 647 Magnet Power Supply User’s Manual Options & Accessories 6-6 This Page Intentionally Left Blank

Page 62 - RES? Resolution Query

Lake Shore Model 647 Magnet Power Supply User’s Manual Magnetic Units A-1APPENDIX A UNITS FOR MAGNETIC PROPERTIES Conversion from CGS to SI UnitsQu

Page 63 - 6.4 ACCESSORIES

Lake Shore Model 647 Magnet Power Supply User’s Manual Magnetic Units A-2 This Page Intentionally Left Blank

Page 64

Lake Shore Model 647 Magnet Power Supply User’s Manual Mainframe Remote Operation B-1APPENDIX B MAINFRAME CONTROL BUS OPERATION B1.0 GENERAL There a

Page 65 - APPENDIX A

Lake Shore Model 647 Magnet Power Supply User’s Manual Mainframe Remote Operation B-2B4.0 CONTROL BUS SERIAL INTERFACE CONFIGURATION Configure the

Page 66 - Magnetic Units

Lake Shore Model 647 Magnet Power Supply User’s Manual Mainframe Remote Operation B-3B6.0 CONTROL BUS SERIAL INTERFACE OPERATION The host computer i

Page 67 - APPENDIX B

Lake Shore Model 647 Magnet Power Supply User’s Manual Forward vFOREWORD PURPOSE AND SCOPE This manual contains user instructions for the Model 647 S

Page 68

Lake Shore Model 647 Magnet Power Supply User’s Manual Mainframe Remote Operation B-4B7.0 CONTROL BUS SERIAL INTERFACE SAMPLE PROGRAM The followin

Page 69 - Mainframe Remote Operation

Lake Shore Model 647 Magnet Power Supply User’s Manual Mainframe Remote Operation B-5Table B-1 MPS Mainframe Control Bus Remote Command Summary Inpu

Page 70 - Mainframe Remote Operation

Lake Shore Model 647 Magnet Power Supply User’s Manual Mainframe Remote Operation B-6Table B-2 Additional MPS Mainframe Control Bus Remote Commands

Page 71

Lake Shore Model 647 Magnet Power Supply User’s Manual Forward viELECTROSTATIC DISCHARGE Electrostatic Discharge (ESD) may damage electronic parts,

Page 72

Lake Shore Model 647 Magnet Power Supply User’s Manual Forward viiMAGNET QUENCHES For protection during a magnet quench, fit the dewar with pressure